FERRULES
Insulated Panel Connectors | Channel Anchors | Ferrules | Threaded Zinc Inserts
 

Note: Ferrule inserts are for connections only and should not be used for lifting. All ferrule inserts should be set back 1/2" from face off concrete. Standard finish is electroplated. Also available plain (Self Colored).

 

FERRULE LOOP INSERTS
N/C closed end threaded ferrule is welded to a single round loop strut. Intended as a connection insert.

ferrule loop insert.eps

 
Part No. Thread (D) Insert Length (L) Thread Depth (B) Wire Diameter (C) SWL (lbs) Sugges. Edge Dist.
C42F025 1/4”-20 NC 2-3/4” 3/4” 0.243” 650 5”
C42F038 3/8”-16 NC 2-3/4” 3/4” 0.243” 2000 5”
C42F050 1/2”-13NC 2-3/4” 1” 0.262” 2000 5”
C42F058 5/8”-11 NC 3-1/4” 1-1/8” 0.262” 2400 5”
C42F075 3/4”-10 NC 3-1/2” 1-1/8” 0.262” 2400 5”
C42F078 7/8”-9 NC 6” 1-1/8” 0.375” 5300 8”
C42F100 1”-8 NC 6” 1-1/8” 0.375” 5300 8”

Note: SWL provides a factor of safety of approximately 3:1 in 3,000 psi normal weight concrete.
Stainless steel available in some sizes.

 

 
FERRULE ONLY
Plain ferrule can be furnished for fabricating special inserts at the job site. C43FO25SS.jpg
 
Part No. Thread (D) lenght
(L)
Outside dia. (OD)
C43F025 1/4” - 20 NC 1-1/4” 9/16”
C43F038 3/8” - 16 NC 1-1/4” 9/16”
C43F050 1/2” - 13 NC 1-3/8” 11/16”
C43F058 5/8” - 11 NC 1-5/8” 7/8”
C43F075 3/4” - 10 NC 1-5/8” 1”
C43F078 7/8” - 9 NC 1-5/8” 1-1/4”
C43F100 1” - 8 NC 1-5/8” 1-3/8”

Note: SWL provides a factor of safety of approximately 3:1 in 3,000 psi normal weight concrete.
Stainless steel available in some sizes

 

THIN SLAB FERRULE INSERTS
Very versatile insert intended for use as an anchorage insert in relatively thin slab concrete. N/C closed end ferrule insert is welded to parallel struts. Intended as a connection insert. Thin slab ferrule insert.eps

 
Part No. Thread (D) Insert Length (L) Thread Depth (B) SWL (lbs) Suggested Edge Distance
C44F038 3/8”-16 NC 2-3/4” 3/4” 450 2-1/2”
C44F050 1/2”-13 NC 2-3/4” 3/4” 900 2-3/4”
C44F058 5/8”-11 NC 2-3/4” 1” 1000 3”
C44F075 3/4”-10 NC 3-1/4” 1-1/8” 1600 3”
C44F10 1”-8 NC 3-1/2” 1-1/8” 1600 3”

Note: SWL provides a factor of safety of approximately 3:1 in 3,000 psi normal weight concrete

Thin slab ferrule insert.eps

 
Note: Ferrule inserts are for connections only and should not be used for lifting. All ferrule inserts should be set back 1/2" from face off concrete. Standard finish is electroplated. Also available plain (Self Colored).
 
THIN SLAB 4 LEG FERRULE INSERTS
Very versatile insert intended for use as an anchorage insert in relatively thin slab concrete. N/C closed end ferrule insert is welded to 4 "L" shaped legs. Intended as a connection insert.

C52FO753.jpg

 
Part No. Thread (D) Insert Length (L) Thread Depth (B) Wire Dia. (C) Spread (S) SWL (lbs) Sugges. Edge Dist.
C52F0753 3/4”-10 NC 3” 1-1/8” 0.306” 7-1/6” 2650 7”
C52F104 1”-8 NC 4” 1-1/8” 0.375” 9-3/8” 4000 9”

Note: SWL provides a factor of safety of approximately 3:1 in 3,000 psi normal weight concrete.

 

EXPANDED FERRULE INSERTS W/2 OR 4 STRUTS
A Ferrule is welded to two or four wire side struts. At the opposite end of the struts from the thread ferrule is an expanded wire embedment coil. These inserts offer a wide degree of casting versatility and high strength for a variety of conditions.

Part No. Thread (D) Insert Length (L) Thread Depth (B) Wire Diameter (C) Spread Length (R) Spread (S) SWL (lbs) Suggested Edge Distance
C57F-3/4 3/4”-10 NC 4-5/8” 1-1/8” 0.440” 1-1/2” 2-1/4” 4250 6”
C57F-1 1”-8 NC 5-5/8” 1-1/8” 0.440” 2-1/4” 2-3/8” 6250 7”

Note:SWL provides a factor of safety of approximately 3:1 in 3,000 psi normal weight concrete.

Expanded ferrule insert.eps

 

FLARED THIN SLAB FERRULE INSERTS - (WING NUT STYLE)
N/C closed end threaded ferrule is welded to two “L” profile closed loop wire struts. Intended as a connection insert in thin slab concrete sections.

flared thin slab insert.eps

 
Part No. Thread (D) Insert Leng. (L) Thread Depth (B) Wire Dia. (C) Spread (S) SWL (lbs) Sugg.. Edge Dist.
C62F05175 1/2”-13 NC 1-3/4” 1” 0.306” 4-3/4” 1200 5”
C62F05827 5/8”-11 NC 2-7/16” 1-1/8” 0.375” 4-3/4” 2500 5”
C62F07527 3/4”-10 NC 2-7/16” 1-1/8” 0.375” 4-7/8” 2650 5”
C62F07535 3/4”-10 NC 3-5/8” 1-1/8” 0.375” 4-7/8” 4500 7”
C62F10278 1”-8 NC 2-7/8” 1-1/8” 0.375” 5-1/8” 2650 5”
C62F10458 1”-8 NC 4-5/8” 1-1/8” 0.375” 5-1/8” 6300 8”

 

Note: Ferrule inserts are for connections only and should not be used for lifting. All ferrule inserts should be set back 1/2" from face off concrete. Standard finish is electroplated. Also available plain (Self Colored).

STRAIGHT FERRULE LOOP INSERTS
N/C closed end threaded ferrule is welded to a closed loop wire strut.

straight ferrule loop.eps
 
Part No. Thread (D) Insert Length (L) Thread Depth (B) Wire Dia. (C) SWL (lbs) Suggested Edge Distance
C64F054 1/2”-13 NC 4-1/8” 1” 0.306” 3000 5”
C64F056 1/2”-13 NC 6-1/8” 1” 0.306” 5000 7”
C64F0584 5/8”-11 NC 4-1/8” 1-1/8” 0.375” 3000 5”
C64F0586 5/8”-11 NC 6-1/8” 1-1/8” 0.375” 5000 7”
C64F0754 3/4”-10 NC 4-1/8” 1-1/8” 0.375” 3000 5”
C64F0756 3/4”-10 NC 6-1/8” 1-1/8” 0.375” 5000 8”
C64F0786 7/8”-9 NC 6-1/8” 1-1/8” 0.375” 5000 8”
C64F106 1”-8 NC 6-1/8” 1-1/8” 0.375” 5000 8”
C64F108 1”- 8 NC 8-1/8” 1-1/8” 0.375” 5000 8”

Note: SWL provides a factor of safety of approximately 3:1 in 3,000 psi normal weight concrete..

 
SEISMIC
Seismic inserts
seicemeic2-1.eps  
Part No. Thread (D) Nominal Depth
(L)
thread depth
(B)
Wire Dia. (C) SWL (lbs) Bar Sugges. Edge Dist.
SEISMIC 4-6” 1”-8 NC 6” 1-1/8” 0.375” 5670 4 Bars 6” or 9”
SEISMIC 4-8” 1”-8 NC 8” 1-1/8” 0.375” 5670 4 Bars 6” or 9”

Note:SWL provides a factor of safety of approximately 3:1in 3,000 psi normal weight concrete.

   
   
Note: Ferrule inserts are for connections only and should not be used for lifting. SWL based on 3:1 safety factor. All ferrule inserts are electro plated.
 