STRAIGHT COIL LOOP INSERTS
Coil is welded to a single wire closed loop.

Part No. Thread (D) Insert Length (L) Body Length (B) Wire Dia. (C) SWL (lbs) Edge Dist.
C16B0540 1/2” coil 4” 1-3/16” 0.306” 2250 5”
C16B0560 1/2” coil 6” 1-3/16” 0.306” 3000 7”
C16B0524 1/2” coil 24” 1-3/16” 0.306” 3000 7”
C16B07540 3/4” coil 4” 1-5/8” 0.375” 2250 5”
C16B07560 3/4” coil 6” 1-5/8” 0.375” 3750 7”
C16B1040 1” coil 4” 2-1/16” 0.375” 3750 5”
C16B1050 1” coil 5” 2-1/16” 0.375” 3750 6”
C16B1060 1” coil 6” 2-1/16” 0.375” 3750 7”
C16B1080 1” coil 8” 2-1/16” 0.375” 3750 9”

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete.
CONAC does not recommend using 1/2" inserts for lifting.

 

DOUBLE FLARED COIL LOOP INSERTS
Second coil loop adds significant capacity in both shear and tension.

Part No. Thread (D) Insert Length (L) Body Length (B) Wire
Dia. (C)
SWL (lbs) S
C17B1012 HD 1” 12” 2-1/16” 0.440” 13500 5-3/4”
C17B-1-1/4” X 12 HD 1-1/4” 12” 2-3/8” 0.440” 13500 5-3/4”
C17B 1-1/2” x 12 HD 1-1/2” 12” 2-9/16” 0.440” 13500 5-3/4”

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete

 

SINGLE FLARED
COIL LOOP INSERTS

Coil is welded to a singled flared wire loop strut.

Part No. Thread (D) Insert Length (L) Body Length (B) Wire
Dia. (C)
Loop Spread (S) SWL (lbs) Sugg. Edge
Dist.
C18B0540 1/2” 4” 1-3/16” 0.306” 3-1/8” 3000 6”
C18B0512 1/2” 12” 1-3/16” 0.306” 3-1/8” 3000 20”
C18B07540 3/4” 4” 1-5/8” 0.306” 3-1/2” 3000 6”
C18B07560 3/4” 6” 1-5/8” 0.375” 3-1/2” 4750 9”
C18B0759 HD 3/4” 9” 1-5/8” 0.440” 5-5/8” 8000 15”
C18B07512HD 3/4” 12” 1-5/8” 0.440” 5-5/8” 8000 20”
C18B109 HD 1” 9” 2-1/16” 0.440” 5-5/8” 8000 15”
C18B1012HD 1” 12” 2-1/16” 0.440” 5-3/4” 8000 20”

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete.
CONAC does not recommend using 1/2" inserts for lifting.

 

DOUBLE FLARED CRISS-CROSS COIL LOOP INSERTS
Second coil loop adds significant capacity in both shear and tension.

Part No. Thread (D) Insert Length (L) Body Length (B) Wire
Dia. (C)
Loop Spread (S) SWL (lbs)
C33B 10x12-1/2” S 1” 12-1/2” 2-1/16” 0.375” 5-9/16” 9500
C33B 10 x 12-1/2” HD 1” 12-1/2” 2-1/6” 0.440” 5-3/4” 13500

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete.

 

THIN SLAB 4 LEG COIL INSERTS
Very versatile insert intended for use for lifting and handling thin slab concrete. The coil is welded to four “L” shaped legs.

Part No. Thread (D) Insert Length (L) Body Length (B) Wire Dia. (C) Spread (S) SWL (lbs) Struts
C53C0753 3/4” 3” 1-5/8” 0.306” 7-1/16” 2000 4
C53C07540 3/4” 4” 1-5/8” 0.306” 7-1/16” 2000 4
C53C0755 3/4” 5” 1-5/8” 0.375” 7-1/16” 2500 4
C53C1035 1” 3-1/2” 2-1/16” 0.375” 9-3/8” 3000 4
C53C1040 1” 4” 2-1/16” 0.375” 9-3/8” 3000 4
C53C1055 1” 5-1/2” 2-1/16” 0.375” 9-3/8” 3000 4
C53C10612 W/6 1” 6-1/2” 2-1/16” 0.375” 9-3/8” 3000 6
C53C1240 1-1/4” 4” 2-1/16” 0.375” 9-3/4” 3000 4

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete.

 

EXPANDED COIL INSERTS
W/2 OR 4 STRUTS

Coil is welded to dual flared wire loop struts. Intended for use for heavy anchorage conditions. Inserts located at the end of either two or four wire connecting struts.

Part No. Struts Thread (D) Insert Length (L) Body Length (B) Wire Dia. (C) Overall Width (G) SWL (lbs)
C56C-3/4 2 3/4” 4-1/2” 1-5/8” 0.440” 2-1/8” 4250
C56C-1 2 1” 5-1/2” 2-1/16” 0.440” 2-3/4” 6250
C58C-1-1/4 4 1-1/4” 7-1/2” 2-3/8” 0.440” 3” 12000
C60C-1-1/2 6 1-1/2” 9-1/2” 2-9/16” 0.440” 3” 16250

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete.

 

FLARED THIN SLAB COIL INSERT - WING NUT STYLE
Coil is welded to two “L” profile closed loop wire struts. Intended for handling thin slab concrete sections.
Part No. Thread (D) Insert Length (L) Body Length (B) Wire Dia. (C) Spread (S) SWL (lbs) Sugg. Edge Dist.
C63C05175 1/2” 1-3/4” 1-3/16” 0.223” 4-1/2” 950 4”
C63C0752516 3/4” 2-5/16” 1-5/8” 0.375” 4-7/8” 2000 5”
C63C075312 3/4” 3-1/2” 1-5/8” 0.375” 4-7/8” 3400 10”
C63C07540 3/4” 4” 1-5/8” 0.375” 4-7/8” 3400 10”
C63C102516 1” 2-5/16” 2-1/16” 0.375” 5-1/4” 2000 5”
C63C1030 1” 3” 2-1/16” 0.375” 5-1/4” 2980 8”
C63C10350 1” 3-1/2” 2-1/16” 0.375” 5-1/4” 3400 10”
C63C1040 1” 4” 2-1/16” 0.375” 5-1/4” 3400 10”
C63C10412 1” 4-1/2” 2-1/16” 0.375” 4-1/4” 4750 10”

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete.
CONAC does not recommend using 1/2" inserts for lifting.

 
SINGLE
PICK UP
COIL INSERTS

Used for face lifting of flat wall panels.
Part No. Thread (D) Insert Length (L) SWL (lbs)
C1T10550 1” 5-1/2” 3750
C1T10650 1” 6-1/2” 5000
C1T10750 1” 7-1/2” 6480
C1T10950 1” 9-1/2” 8100

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete.

 
COIL TIES
Very versatile insert intended for use for lifting. The coil is welded to two or four strut also available
with Shear Bar. Intended as a strong and versatile form tie insert.
Part No. Struts Thread (D) Insert Length (L) Body Length (B) Wire Diameter (C) Overall Width (G) SWL (lbs)
CT2-3/4X5 2 3/4” 5” 1-5/8” 0.375” 1-5/8” 4250
CT2-3/4X6 2 3/4” 6” 1-5/8” 0.375” 1-5/8” 4500
CT2-3/4X8 2 3/4” 8” 1-5/8” 0.375” 1-5/8” 6000
CT2-3/4X21 2 3/4” 21” 1-5/8” 0.375” 1-5/8” 6000
CT2-1X6 2 1” 6” 2-1/16” 0.440” 2-3/8” 6000
CT2-1-1/4X8 2 1-1/4” 8” 2-1/16” 0.440” 2-1/2” 7500
CT4-3/4X6 4 3/4” 6” 1-5/8” 0.440” 1-3/4” 6000
CT4-1X6 4 1” 6” 2-1/16” 0.440” 2-3/8” 6000
CT4-1X8 4 1” 8” 2-1/16” 0.440” 2-3/8” 9000
CT4-1X12 4 1” 12” 2-1/16” 0.440” 2-3/8” 9000
CT4-1X15 4 1” 15” 2-1/16” 0.440” 2-3/8” 9000
CT4-1-1/4”X8 4 1-1/4” 8” 2-3/8” 0.440” 2-1/2” 9000
CT4-1-1/4”X12 4 1-1/4” 12” 2-3/8” 0.440” 2-1/2” 13500
CT4-1-1/4”X18 4 1-1/4” 18” 2-3/8” 0.440” 2-1/2” 13500
CT4-1X12S 4 1” 12” 2-1/16” 0.440” 2-3/4” 9000
CT4-1X15S 4 1” 15” 2-1/16” 0.440” 2-3/4” 9000
CT4-1X18S 4 1” 18” 2-1/16” 0.440” 2-3/4” 9000
CT6-1-1/4X10 6 1-1/4” 10” 2-3/8” 0.440” 2-3/4” 12000

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete.

 
STRAIGHT CRISS-CROSS COIL INSERTS
Ideal for edge lifing applications due to high strength provided by
the 4 struts design.
Part No. Thread (D) Insert Length (L) Wire Dia. (C) Body length (B) SWL (lbs)
FCC 3/4X9 3/4” 9” 0.375” 1-5/8” 3,700
FCC1X12HD 1” 12” 0.440” 2-1/16” 6,500
FCC1-1/4X12HD 1-1/4” 12” 0.440” 2-3/8” 7,500

Note: SWL provides a factor of safety of approximately 4:1 in 3,000 psi normal weight concrete.

 
COIL NUTS
Part No. Thread (D) Thick. (T) Across Flat (F) Tension Strength (lbs)
CN05 1/2” 1/2” 3/4” 1800
CN075 3/4 “ 3/4” 1-1/8” 3600
CN10 1” 1” 1-1/2” 7200

Standard finish plain (self color)

 

COIL BOLTS

Part No. Thread (D) Length (L) Head Thick. (T) Across Flats (F) Tensile Strength (lbs)
CB0515 1/2” 1-1/2” 3/8” 3/4” 2700
CB0520 1/2” 2” 3/8” 3/4” 2700
CB0525 1/2” 2-1/2” 3/8” 3/4” 2700
CB0530 1/2” 3” 3/8” 3/4” 2700
CB0540 1/2” 4” 3/8” 3/4” 2700
CB0550 1/2” 5” 3/8” 3/4” 2700
CB0560 1/2” 6” 3/8” 3/4” 2700
CB07520 3/4” 2” 1/2” 1-1/8” 3600
CB07525 3/4” 2-1/2” 1/2” 1-1/8” 3600
CB07530 3/4” 3” 1/2” 1-1/8” 3600
CB07540 3/4” 4” 1/2” 1-1/8” 3600
CB07550 3/4” 5” 1/2” 1-1/8” 3600
CB1040 1” 4” 11-16” 1-1/2” 7200

Standard finish plain (self color)

 

COIL RODS

Part No. Size (DXL) Tensile SWl (LBS) Shear SWl (LBS)
CR 1/2 X 6’ 1/2” X 6 ‘ 3600 2400
CR 3/4 X 6’ 3/4” X 6’ 7200 4800
CR 1 X 6’ 1” X 6 ‘ 15000 10000
CR 1-1/4” X 6’ 1-1/4” X 6’ 22400 15000
CR 1-1/2” x 6’ 1-1/2” X 6 ‘ 27000 18000

Standard finish plain (self color)

 
PLASTIC COIL PROTECTOR
Looks like coil bolt. Use for keeping the coil clean during casting. Can be nailed to wood forms.
Part No. Thread Size T L Color Quantity Per Box
PCP-05 1/2” COIL 1/2” 2-1/4” white 200
PCP-075 3/4” COIL 3/4” 3” white 200
PCP-01 1” COIL 3/4” 4-1/2” white 200
 
COIL THREADED PLASTIC PLUGS
Can be nailed to wood forms.
Part No. Thread Size Color Quantity Per Box
TP4016C 1/2” COIL lt. blue 100
TP4018C 3/4” COIL dk. green 100
 
SWIVEL LIFTING PLATES
For safe lifting, Lifting Plates must have full bearing and be tightened securely. 5:1 safety factor.
Part No. Size Min. Bolt Length Capac. (LBS)
SWLP75 3/4” 4” 9,000
SWLP10 1” 5” 9,000
 
Part No. Size Min. Bolt Length Capac. (LBS)
SWLP10-D 1” 5” 9,000
 
Part No. Size Min. Bolt Length Capac. (LBS)
SWLP15-D 1-1/2” 6” 13,500
 
COIL LIFTING LOOPS
Most economical lifting units for this system. Manufactured from flexible wire rope. For tension only - limited to 30 degrees from vertical. Galvanized cable loop with mill finished threaded stud.
Part No. Diameter (D) Capacity Load (LBS) A C
CLL50 1/2” 2,000 5-1/2” 2-1/4”
CLL75 3/4” 5,000 8-1/2” 2-3/4”
CLL100 1” 8,000 10-3/4” 2-3/4”

Note: SWL provides a factor of safety of approximately 5:1 in 3,000 psi normal weight concrete.

 
EYE BOLT
Forged steel: one piece coil threaded eye bolt for tension lifting only.
Part No. Thread (D) Thread Length (L) Outside Dia. (A) Inside Dia. (B) SWL (LBS)
EYE BOLT 3/4X2 EYE BOLT 3/4” 2” 2-7/8” 1-1/2” 3,600
EYE BOLT 1X2-1/2 EYE BOLT 1” 2-1/2” 3-1/2” 1-3/4” 6,400

Note: SWL provides a factor of safety of approximately 5:1 in 3,000 psi normal weight concrete.

 
 